We've provided details of some of the most important AT commands that you will encounter when using RockBLOCK. Much of this documentation is extracted directly from Iridium's own AT command reference.

The full AT command reference can be downloaded here: Iridium AT Command Guide, version 5

All commands begin with a prefix of AT

The maximum number of characters in a command string is 128. This limit is often encountered when using the +SBDWT command. To send longer messages, review the alternative form of the command, or consider the +SBDWB command